Dome Loading Down-stream Pressure Regulation
This page describes our standard locked and variable pilot pressure dome loading, down-stream pressure controller ranges. Suitable for both liquid or gas service these regulators can either be set-up from an external source, (such as a separate gas bottle), or directly loaded from up-stream inlet gas pressure. Pilot loading can be from a fixed or a variable pressure source depending upon required down-stream performance.
We are able to supply models suitable for N.A.C.E, HIGH PURITY or OXYGEN service but please always specify this requirement with your enquiry or when placing an order.
|
|
Series 101 Spring / Dome Loading regulator enabling variable outlet pressures & low pressure 'switching' features. Max. INLET pressure 414bar. This type of controller can be operated with pre-set spring together with a pilot dome signal to provide infinite OUTLET ranges betwen 0.5 & 414bar. Port options 1/2" to 3" are available & various material versions can be selected. |
 |
Series 102 High Capacity / High Accuracy dome loading pressure controller. Max. INLET pressure 414bar. This controller is capable of operation with locked dome or pilot signal to provide infinite OUTLET ranges betwen 0 & 414bar. Port options between 1/2" and 3" are available and various material options may be selected. Special high ratio dome sensing heads and pressure multiplier headworks can also be used for closed loop feed-back control systems. |
Please call if you require advice on product selection.
Tel: ++44(0)1509 264242 Fax: ++44(0)1509 263308 enquiry
---------------------------------------------------------------------------------------------------------
|